33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s

Product Details
Customization: Available
Shell Material: Steel Plate
Voltage Level: Medium Voltage
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (22)
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
  • 33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current> 800A, Duration Time: 10s
Find Similar Products

Basic Info.

Installation
Fixed
Structure
Cabinet
Current
AC
Frequency
50/60Hz
Voltage
33kv
Insulation Level
a/F
Rated Short Circuit Power, (kVA)
~15240kVA
Rated Continuous Neutral Current
24.8 a
Rated Short Time Rating Neutral Current
> 800A
Rated Short Time Rating Duratio
20s
Vetor Group
Zig-Zag
Transport Package
Naked
Trademark
OEM
Origin
China
HS Code
8537209000
Production Capacity
100set/Month

Packaging & Delivery

Package Size
179.00cm * 85.00cm * 165.00cm
Package Gross Weight
3600.000kg

Product Description



Our company produces professional 6kV, 10kV, 20kV, and 35kV grounding transformers, including epoxy cast dry-type and oil immersed grounding transformers, as well as single-phase grounding transformers specifically designed for motors.
A. Iron core
High quality cold-rolled oriented silicon steel sheets are used, with 45 ° full diagonal joints. The iron yoke is clamped with a through screw, and the core column is tied with fiberglass tape. The surface of the iron core is sprayed with silicone resin adhesive to prevent moisture, tighten and minimize noise.
B. Winding
Both the inner and outer windings are made of high-quality copper wires, with a segmented cylindrical structure to enhance interlayer insulation. Vacuum drying technology is used, and the formed windings have good electrical performance, high mechanical strength, and low local discharge capacity.
C. Epoxy resin is not filled with vacuum casting for dry-type grounding transformers, which has stronger smoke and water resistance compared to non encapsulated products. The oil immersed grounding transformer adopts a fully sealed structure and uses corrugated fins for heat dissipation to eliminate the oil storage tank. The oil tanks are sealed with oil resistant rubber strips to prevent the transformer oil from coming into contact with air. The transformer oil does not come into contact with air, ensuring the insulation performance and service life of the product. The product has the characteristics of small footprint, beautiful appearance, and maintenance free.
D. Protective device
Oil immersed grounding transformers are equipped with pressure relief valves and gas relays, as well as oil level gauges for easy monitoring of transformer oil levels at any time. The dry-type grounding transformer is equipped with a temperature control device and has remote transmission function, making it convenient to inspect the operating temperature of the product at any time.

3.Main Technical Parameter

Types SJD Dry or Oil-immersed
Connection group (ZN (Zigzag), ZNyn, YNd(open), Ii0)
­­Voltage Up to 36kV
Current Up to 3000A*
Duty (Seconds) 10/30/60 or others
Cooling Method ONAN, ONAF, AN, AF
Frequency 50Hz / 60Hz
Installation Indoor / Outdoor
Ambient Temperature -40 ºC to 40 ºC*
Standards IEC 60076-6, IEC60076-1,IEEE
Enclosure Options Transformer cabinet for any IP degrees with:
-CT
-VT
-Isolation switch

 Note:  Neutral Short time Current I0=IG, Neural Zero Sequence Impedance Z0=Zphase /3
           ±5% off load tap change switch
           Declare Z0 before producing if not a self-limiter
           Z0 tolerance ≤10%
           If a resistor will be connected between the brought out Neutral and ground, choose Z0 as small as possible, and better make Z0+R= VLN/IG

 
1 Manufacturing standards   IEC-60076/289
2 Type of transformer (Sealed or Breath)   Breath
3 Service condition   outdoor type
4 Short time power kVA 15240
5 Auxiliary winding capacity kVA N/A
6 System Nominal Voltage kV 33
7 System Max.Voltage kV 36
8 Secondary voltage kV N/A
9 Secondary Rated current A N/A
10 Short time current for neutral A 800
11 Duration of short time current S 10
12 continuous current A 10
13 Rated frequency Hz 50
14 Winding connection   ZN
15 Zero-sequence impedance Omiga/phase 24
16 Short     circuit     impedance      (  Auxiliary % 6
17 Tapping method   no laod
  Tapping range   N/A
18 Maximum temperature rise at rated power:    
a)Maximum winding temperature rise K 55
b)Maximum oil Temperature rise K 40
c) Hot spot temperature ºC 98
d) Core and contruction rise K 75
19 No load loss kW 1.95
20 Load losses at 75 °C(Auxiliary winding) kW  
21 Total losses at 75°C(Auxiliary winding) kW  
22 Insulation level    
a) Primary side KV BIL 170 AC 70
b) Secondary side KV N/A
23 Maximum flux density in Core Tesla <1.6
24 Sound level (sound pressure level) dB <50
25 Cooling   ONAN
26 Type and Material of Windings\core and oil:    
a) Primary winding   CU
b) Secondary winding   N/A
c) Core material   30Q120
d) Insulating oil Class 25#Mineral oil
27 Insulation of Windings:    
a) Primary winding   Cable insulating Paper
b) Secondary winding   Cable insulating Paper
c) Tapping and tapping connections   Cable insulating Paper
d) Level of Insulating material Class A
28 Line terminals (Top of tank or Top  Box ,    
(a)  Primary   N/A
(b)  Secondary   N/A
29 Type of tank (radiator or corrugated)   corrugated
30 Bushing creepage distance    
a. Primary mm/kv 25
a. Secondary mm/kv N/A
31 Material of Transformer Tank   Iron
32 Thickness material of Transformer Tank:    
a)Top mm 8
b)Bottom mm 8
c)Sides mm 6
d)Corrugated wall or radiator mm 1.2
e)Shot blasting and two finish coats Yes/No Yes
33 Thickness of paint μm 120
34 Weights    
a. Net weight of insulating oil kgs 690
b. Weight of activepart kgs 2400
c. Total weight of transformer kgs 3600
35 Transformer     dimensions     including     all    
a) Length mm 1790
b) Breadth mm 850
c) Height mm 1650
36 Color of transformer   As per required
  Accessories/Fittings supplied    
1 Oil temperature indicator Yes/no Yes
2 Oil level Indicator Yes/no Yes
3 Conservator with buchholz relay(Sixin) Yes/no Yes
4 Pressure relieve device yes/no Yes
5 Conservator yes/no Yes
6 Support lugs Yes/no Yes
7 Lifting lugs Yes/no Yes
8 Earthing terminals for tanks Yes/no Yes
9 Danger Plate Yes/no Yes
10 Rating plates Yes/no Yes
11 Current  Transformer   between   Neutral  &
Earth
Yes/no No
12 Mounting Bi-directional rollers Yes/no No
B SERVICE CONDITION    
1 Altitude Meters 0~2000
2 Max Temperatures Degree 55

 
SJD-Dry or Oil-immersed Earthing transformer(Popular products)
Item&Specs. Ground-fault Current I0 Time Impedance Z0
SJD-4.16KV/200A-10S 200A 10s 2.4~12.0Ω
SJD-4.16KV/400A-10S 400A 10s 1.2~6.0Ω
SJD-4.16KV/600A-10S 600A 10s 0.8~4.0Ω
SJD-12.47KV/200A-10S 200A 10s 7.2-36.0Ω
SJD-12.47KV/400A-10S 400A 10s 3.6-18.0Ω
SJD-12.47KV/600A-10S 600A 10s 2.4~12.0Ω
SJD-13.2KV/200A-10S 200A 10s 7.6~38.1Ω
SJD-13.2KV/400A-10S 400A 10s 3.8~19.1Ω
SJD-13.2KV/600A-10S 600A 10s 2.5~12.7Ω
SJD-13.8KV/200A-10S 200A 10s 8.0~39.8Ω
SJD-13.8KV/400A-10S 400A 10s 4.0~19.9Ω
SJD-13.8KV/600A-10S 600A 10s 2.6~13.3Ω
SJD-13.8KV/800A-10S 800A 10s 2.0~10.0Ω
SJD-24.94KV/200A-10S 200A 10s 14.4~72.0Ω
SJD-24.94KV/400A-10S 400A 10s 7.2~36.0Ω
SJD-24.94KV/600A-10S 600A 10s 4.8~24.0Ω
SJD-24.94V/800A-10S 800A 10s 3.6~18.0Ω
SJD-24.94V/1000A-10S 1000A 10s 2.8~14.4Ω
SJD-34.5KV/200A-10S 200A 10s 14.1~70.7Ω
SJD-34.5KV/400A-10S 400A 10s 7.0~35.4Ω
SJD-34.5KV/600A-10S 600A 10s 4.7~23.6Ω
SJD-34.5V/800A-10S 800A 10s 34~17.7Ω
SJD-34.5V/1000A-10S 1000A 10s 2.8~14.2Ω

 

33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s33kv Oil Immersed Grounding /Earthing Transformer, Short Time Power 15240kVA 50/60Hz, Rated Short Time Current&gt; 800A, Duration Time: 10s

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now