Customization: | Available |
---|---|
Shell Material: | Steel Plate |
Voltage Level: | Medium Voltage |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Our company produces professional 6kV, 10kV, 20kV, and 35kV grounding transformers, including epoxy cast dry-type and oil immersed grounding transformers, as well as single-phase grounding transformers specifically designed for motors.
A. Iron core
High quality cold-rolled oriented silicon steel sheets are used, with 45 ° full diagonal joints. The iron yoke is clamped with a through screw, and the core column is tied with fiberglass tape. The surface of the iron core is sprayed with silicone resin adhesive to prevent moisture, tighten and minimize noise.
B. Winding
Both the inner and outer windings are made of high-quality copper wires, with a segmented cylindrical structure to enhance interlayer insulation. Vacuum drying technology is used, and the formed windings have good electrical performance, high mechanical strength, and low local discharge capacity.
C. Epoxy resin is not filled with vacuum casting for dry-type grounding transformers, which has stronger smoke and water resistance compared to non encapsulated products. The oil immersed grounding transformer adopts a fully sealed structure and uses corrugated fins for heat dissipation to eliminate the oil storage tank. The oil tanks are sealed with oil resistant rubber strips to prevent the transformer oil from coming into contact with air. The transformer oil does not come into contact with air, ensuring the insulation performance and service life of the product. The product has the characteristics of small footprint, beautiful appearance, and maintenance free.
D. Protective device
Oil immersed grounding transformers are equipped with pressure relief valves and gas relays, as well as oil level gauges for easy monitoring of transformer oil levels at any time. The dry-type grounding transformer is equipped with a temperature control device and has remote transmission function, making it convenient to inspect the operating temperature of the product at any time.
3.Main Technical Parameter
Types | SJD Dry or Oil-immersed |
Connection group | (ZN (Zigzag), ZNyn, YNd(open), Ii0) |
Voltage | Up to 36kV |
Current | Up to 3000A* |
Duty (Seconds) | 10/30/60 or others |
Cooling Method | ONAN, ONAF, AN, AF |
Frequency | 50Hz / 60Hz |
Installation | Indoor / Outdoor |
Ambient Temperature | -40 ºC to 40 ºC* |
Standards | IEC 60076-6, IEC60076-1,IEEE |
Enclosure Options | Transformer cabinet for any IP degrees with: -CT -VT -Isolation switch |
Rated voltage | 33 kV |
- Type | Oil immersed |
- Installation | outdoor |
- Rated voltage, (kV) | 33 |
- Rated short circuit power, (kVA) | ~15240 |
- Rated continuous neutral current | ~24.8 A |
- Rated short time rating: | |
. Neutral current, A | > 800 |
. Duration, sec | 20 |
- Short-Circuit level of the System, kA | 25 |
- Method of cooling | ONAN |
- Power frequency withstand test voltage of bushings, (winding / bushings), (kV) | 70/95 |
- Impulse withstand test voltage (winding / bushings), (kV) | 170 /250 |
- Vector group | Zig-zag |
- Zero sequence impedance (ohm/phase) | ~71.5 |
. Zero-sequence reactance (X0) | / |
. Ratio of X0/R0 | / |
- Maximum ambient temperature, oC | 40 |
- Continuous Maximum Rating Temperature Rises | |
· Windings (Temperature rise measured by resistant method) | 65K |
· Top Oil (Temperature rise measured by thermometer) | 60K |
- Inbuilt neutral CT rating | TBA during detailed design |
· Rated current, Primary (A) | 400-800 |
· Rated current, Secondary (A) | 1 |
· Number of cores | 2 |
· Accuracy class | PX |
· Burden | 30VA |
- Tank type | Bolted type cover |
- Dimensions and weights | |
a. Overall length, (mm) | ~3000 |
b. Overall width, (mm) | ~1700 |
c. Overall height, (mm) | ~2750 |
d. Total weight including oil | ~ 8400 |
e. Weight of oil, (kg) | ~ 3000 |
f. Weight of core and windings, (kg) | ~4000 |
g. Shipping weight of the heaviest package, (kg) | ~8400 |
- Standards applied | IEC 60076 |
Item&Specs. | Ground-fault Current I0 | Time | Impedance Z0 |
SJD-4.16KV/200A-10S | 200A | 10s | 2.4~12.0Ω |
SJD-4.16KV/400A-10S | 400A | 10s | 1.2~6.0Ω |
SJD-4.16KV/600A-10S | 600A | 10s | 0.8~4.0Ω |
SJD-12.47KV/200A-10S | 200A | 10s | 7.2-36.0Ω |
SJD-12.47KV/400A-10S | 400A | 10s | 3.6-18.0Ω |
SJD-12.47KV/600A-10S | 600A | 10s | 2.4~12.0Ω |
SJD-13.2KV/200A-10S | 200A | 10s | 7.6~38.1Ω |
SJD-13.2KV/400A-10S | 400A | 10s | 3.8~19.1Ω |
SJD-13.2KV/600A-10S | 600A | 10s | 2.5~12.7Ω |
SJD-13.8KV/200A-10S | 200A | 10s | 8.0~39.8Ω |
SJD-13.8KV/400A-10S | 400A | 10s | 4.0~19.9Ω |
SJD-13.8KV/600A-10S | 600A | 10s | 2.6~13.3Ω |
SJD-13.8KV/800A-10S | 800A | 10s | 2.0~10.0Ω |
SJD-24.94KV/200A-10S | 200A | 10s | 14.4~72.0Ω |
SJD-24.94KV/400A-10S | 400A | 10s | 7.2~36.0Ω |
SJD-24.94KV/600A-10S | 600A | 10s | 4.8~24.0Ω |
SJD-24.94V/800A-10S | 800A | 10s | 3.6~18.0Ω |
SJD-24.94V/1000A-10S | 1000A | 10s | 2.8~14.4Ω |
SJD-34.5KV/200A-10S | 200A | 10s | 14.1~70.7Ω |
SJD-34.5KV/400A-10S | 400A | 10s | 7.0~35.4Ω |
SJD-34.5KV/600A-10S | 600A | 10s | 4.7~23.6Ω |
SJD-34.5V/800A-10S | 800A | 10s | 34~17.7Ω |
SJD-34.5V/1000A-10S | 1000A | 10s | 2.8~14.2Ω |